™ IMAGETEAM™ 2020/5620Cordless SystemSystem Manual
iiConnecting the Base with USB... 1-18IBM SurePos ...
6 - 22 IMAGETEAM™ 2020/5620 System ManualUPC E0 and UPC E1 Addenda SeparatorWhen this feature is on, there is a space between the data from the bar co
IMAGETEAM™ 2020/5620 System Manual 6 - 23UPC E0 AddendaThis selection adds 2 or 5 digits to the end of all scanned UPC E data.Default = Off for both 2
6 - 24 IMAGETEAM™ 2020/5620 System ManualEAN/JAN 13 AddendaThis selection adds 2 or 5 digits to the end of all scanned EAN/JAN 13 data.Default = Off f
IMAGETEAM™ 2020/5620 System Manual 6 - 25ISBN TranslateThis selection causes EAN-13 Bookland symbols to be translated into their equivalent ISBN numbe
6 - 26 IMAGETEAM™ 2020/5620 System ManualEAN/JAN 8 AddendaThis selection adds 2 or 5 digits to the end of all scanned EAN/JAN 8 data.Default = Off for
IMAGETEAM™ 2020/5620 System Manual 6 - 27MSI<Default All MSI Settings>MSIMSI Check CharacterDifferent types of check characters are used with MS
6 - 28 IMAGETEAM™ 2020/5620 System ManualMSI Message LengthScan the bar codes below to change the message length. Refer to Message Length on page 6-2
IMAGETEAM™ 2020/5620 System Manual 6 - 29RSS-14< Default All RSS-14 Settings >RSS-14RSS Limited< Default All RSS Limited Settings >RSS Lim
6 - 30 IMAGETEAM™ 2020/5620 System ManualRSS Expanded< Default All RSS Expanded Settings >RSS ExpandedRSS Expanded Message LengthScan the bar co
IMAGETEAM™ 2020/5620 System Manual 6 - 31Identifier will be reported as “]C1”. If RSS Emulation is selected, the AIM Symbology Identifier will be rep
iiiGood Read Delay ...3-3User-Specified Good Read Delay...
6 - 32 IMAGETEAM™ 2020/5620 System ManualKorea Post Code<Default All Korea Post Code Settings>Korea Post CodeKorea Post Message LengthScan the b
IMAGETEAM™ 2020/5620 System Manual 6 - 33PosiCode A and BYou have to have PosiCode A and B on to read any of the PosiCode symbologies.PosiCode Message
6 - 34 IMAGETEAM™ 2020/5620 System ManualTrioptic CodeTrioptic Code is used for labeling magnetic storage media.Note: If you are going to scan Code 32
IMAGETEAM™ 2020/5620 System Manual 6 - 35Code 16K<Default All Code 16K Settings>Code 16KCode 16K Message LengthScan the bar codes below to chang
6 - 36 IMAGETEAM™ 2020/5620 System ManualCode 49Code 49 Message LengthScan the bar codes below to change the message length. Refer to Message Length
IMAGETEAM™ 2020/5620 System Manual 7 - 17Interface KeysKeyboard Function RelationshipsThe following Keyboard Function Code, Hex/ASCII Value, and Full
7 - 2 IMAGETEAM™ 2020/5620 System ManualThe last five characters in the Full ASCII “CTRL”+ column ( [ \ ] 6 - ), apply to US only. The following cha
IMAGETEAM™ 2020/5620 System Manual 7 - 3Supported Interface KeysASCII HEXIBM AT/XT and PS/2 Compatibles, WYSE PC/ATSupported KeysIBM XTs and Compatibl
7 - 4 IMAGETEAM™ 2020/5620 System ManualSupported Interface Keys ASCIIHEXIBM, Memorex Telex (102)*Supported KeysMemorex Telex (88)**Supported KeysNUL
IMAGETEAM™ 2020/5620 System Manual 7 - 5Supported Interface KeysASCII HEXEsprit 200, 400ANSISupported KeysEsprit 200, 400ASCIISupported KeysEsprit 200
ivChapter 5 - Data FormattingData Format Editor Introduction... 5-1To Add a Data Format ...
7 - 6 IMAGETEAM™ 2020/5620 System ManualSupported Interface KeysASCII HEXApple Mac/iMac Supported KeysNUL 00 ReservedSOH 01 Enter/Numpad EnterSTX 02 C
IMAGETEAM™ 2020/5620 System Manual 8 - 18UtilitiesTo Add a Test Code I.D. Prefix to All SymbologiesThis selection allows you to turn on transmission
8 - 2 IMAGETEAM™ 2020/5620 System ManualResetting the Standard Product DefaultsIf you aren’t sure what programming options are in your scanner, or you
IMAGETEAM™ 2020/5620 User’s Guide 9 - 19Visual Menu 2003Visual Menu 2003 IntroductionVisual Menu 2003 provides the ability to configure a scanning de
9 - 2 IMAGETEAM™ 2020/5620 User’s Guide4. When prompted, select Save File, and save the files to the c:\windows\temp directory. 5. Once you have fini
IMAGETEAM™ 2020/5620 System Manual 10 - 110Serial Programming CommandsThe serial programming commands can be used in place of the programming bar cod
10 - 2 IMAGETEAM™ 2020/5620 System ManualData The new value for a menu setting, identified by the Tag and Sub-Tag.Storage A single character that spec
IMAGETEAM™ 2020/5620 System Manual 10 - 3Concatenation of Multiple CommandsMultiple commands can be issued within one Prefix/Storage sequence. Only
10 - 4 IMAGETEAM™ 2020/5620 System ManualExample #4: What are the device’s settings for all Codabar selections?Enter: cbr?.Response: CBRENA1[ACK],SSX
IMAGETEAM™ 2020/5620 System Manual 10 - 5Menu CommandsSelectionSetting* Indicates defaultSerial Command# Indicates a numeric entryPageBase Charge Mode
vMatrix 2 of 5...6-13Matrix 2 of 5 Message Length...
10 - 6 IMAGETEAM™ 2020/5620 System ManualKeyboard Style*Regular KBDSTY0 2-5Caps Lock KBDSTY1 2-5Shift Lock KBDSTY2 2-5Automatic Caps Lock KBDSTY6 2-5E
IMAGETEAM™ 2020/5620 System Manual 10 - 7Word Length: Data Bits, Stop Bits, and Parity7 Data, 1 Stop, Parity Even232WRD32-97 Data, 1 Stop, Parity Non
10 - 8 IMAGETEAM™ 2020/5620 System ManualWand Emulation Delay Between Blocks5ms WNDDLY0 2-15*50ms WNDDLY1 2-15150ms WNDDLY2 2-15500ms WNDDLY3 2-15Wand
IMAGETEAM™ 2020/5620 System Manual 10 - 9Trigger Mode*Manual Trigger TRGMOD0 3-4Read Time-Out (0 - 300,000 ms) *0TRGSTO#### 3-4Scanner Power Time-Out
10 - 10 IMAGETEAM™ 2020/5620 System ManualPrefixAdd Prefix PREBK2## 4-3Clear One Prefix PRECL2 4-3Clear All Prefixes PRECA2 4-3SuffixAdd Suffix SUFBK2
IMAGETEAM™ 2020/5620 System Manual 10 - 11Codabar Check Char.*No Check Char. CBRCK20 6-4Validate, But Don’t Transmit CBRCK21 6-4Validate, and Transmit
10 - 12 IMAGETEAM™ 2020/5620 System ManualInterleaved 2 of 5 Message LengthMinimum (2 - 80) *4 I25MIN## 6-10Maximum (2 - 80) *80 I25MAX## 6-10Code 9
IMAGETEAM™ 2020/5620 System Manual 10 - 13Code 128Default All Code 128Settings128DFT 6-15Code 128Off 128ENA0 6-16*On 128ENA1 6-15ISBT ConcatenationOn
10 - 14 IMAGETEAM™ 2020/5620 System ManualUPC A Addenda Required*Not Required UPAARQ0 6-19Required UPAARQ1 6-19UPC A Addenda SeparatorOff UPAADS0 6-20
IMAGETEAM™ 2020/5620 System Manual 10 - 15EAN/JAN 13 Addenda Required*Not Required E13ARQ0 6-24Required E13ARQ1 6-24EAN/JAN 13 Addenda SeparatorOff E1
viEAN/JAN 8 ... 6-25EAN/JAN 8 Check Digit ...
10 - 16 IMAGETEAM™ 2020/5620 System ManualPlessey Message LengthMinimum (4 - 48) *4 PLSMIN## 6-28Maximum (4 - 48) *48 PLSMAX## 6-28RSS-14Default All R
IMAGETEAM™ 2020/5620 System Manual 10 - 17PosiCodeOff POSENA0 6-33*On POSENA1 6-33A and B On POSLIM0 6-33A and B and Limited A On POSLIM1 6-33*A and B
10 - 18 IMAGETEAM™ 2020/5620 System Manual
IMAGETEAM™ 2020/5620 System Manual 11 - 111Product SpecificationsIMAGETEAM 5620 Product SpecificationsParameter SpecificationDimensions (Typical):Hei
11 - 2 IMAGETEAM™ 2020/5620 System ManualIMAGETEAM 2020 Product SpecificationsParameter SpecificationDimensions (Typical):Height3.1 inches (7.9 cm)Len
IMAGETEAM™ 2020/5620 System Manual 11 - 3IMAGETEAM 5620 Depth of FieldMinimum Bar WidthMaximum Near FieldMinimum Far Field (no ambient lighting)13 mil
11 - 4 IMAGETEAM™ 2020/5620 System Manual Standard Cable PinoutsKeyboard Wedge10 Pin RJ41 Modular Plugconnects to the base12 Cord shield3 Tied to supp
IMAGETEAM™ 2020/5620 System Manual 11 - 5Standard Cable PinoutsWand Emulation10 Pin Modular Plugconnects to the base12 Cord shield3 Prog 1 (Tied to su
11 - 6 IMAGETEAM™ 2020/5620 System ManualStandard Cable PinoutsSerial Output 10 Pin RJ41 Modular Plugconnects to the base12 Cord shield3 Prog 1 (Tied
IMAGETEAM™ 2020/5620 System Manual 11 - 7Standard Cable PinoutsUSB10 Pin Modular Plugconnects to the base12 Data +3 Tied to supply power4 Supply groun
viiTemporary Visual Menu 2003 Configuration ...8-2Chapter 9 - Visual Menu 2003Visual Menu 2003 Introduction ...
11 - 8 IMAGETEAM™ 2020/5620 System Manual
IMAGETEAM™ 2020/5620 System Manual 12 - 112MaintenanceMaintenanceRepairs and/or upgrades are not to be performed on this product. These services are
12 - 2 IMAGETEAM™ 2020/5620 System ManualReplacing the IT2020 Interface Cable:1. Turn the power to the host system OFF.2. Disconnect the base’s cable
IMAGETEAM™ 2020/5620 System Manual 12 - 3• There is external power or 12 volt host power.• Charge mode is turned on. (See "Base Charge Mode&quo
12 - 4 IMAGETEAM™ 2020/5620 System ManualIf you aren’t sure what programming options have been set in the base, or if you want the factory default set
IMAGETEAM™ 2020/5620 System Manual 13 - 113Customer SupportObtaining Factory ServiceHand Held Products provides service for all its products through
13 - 2 IMAGETEAM™ 2020/5620 System ManualTechnical AssistanceIf you need assistance installing or troubleshooting your scanner, please call your Distr
IMAGETEAM™ 2020/5620 System Manual 13 - 3Held Products determines to its satisfaction that the product is defective due to defects in materials or wor
13 - 4 IMAGETEAM™ 2020/5620 System Manual
IMAGETEAM™ 2020/5620 System Manual A - 1Appendix ASymbology ChartNote: “m” represents the AIM modifier character. Refer to International Technical S
viiiAppendix ASymbology Chart ... A-1ASCII Conversion Chart (Code Page 1252) ...
A - 2 IMAGETEAM™ 2020/5620 System ManualASCII Conversion Chart (Code Page 1252)Note: This table applies to U.S. style keyboards. Certain characters m
IMAGETEAM™ 2020/5620 System Manual A - 331 1F US 191 3F ? 255 5F _ 319 7F128 80€€192 A0 256 C0 À 320 E0 à129 81 193 A1 ¡ 257 C1 Á 321 E1 á130 82 ‚ 194
A - 4 IMAGETEAM™ 2020/5620 System ManualCode Page Mapping of Printed Bar CodesCode pages define the mapping of character codes to characters. If the
Sample SymbolsUPC A0 123456 7890Interleaved 2 of 5Code 128EAN 131234567890Code 1289 780330 290951654EAN 83210 545612380UPC-E
Sample SymbolsCode 93123456-9$Code 2 of 5123456Matrix 2 of 56543210RSS-14(01)00123456789012Code 39CodabarBC321A13579B
Programming ChartACSaveBDiscardFEDNote:If you make an error while scanning the letters or digits (before scanning Save), scan Discard, scan the correc
HHP, Inc.700 Visions DriveP.O. Box 208Skaneateles Falls, NY 13153-02085620-SM Rev B11/04
IMAGETEAM™ 2020/5620 System Manual 1 - 11Getting StartedThe IMAGETEAM 5620 cordless scanning system consists of one IT2020 base and one IT5620 Cordle
1 - 2 IMAGETEAM™ 2020/5620 System ManualUnpacking the SystemAfter you open the shipping carton containing the product, take the following steps:• Chec
IMAGETEAM™ 2020/5620 System Manual 1 - 3Cordless System: Main ComponentsAbout the BatteryUse only the Li-ion battery packs provided by Hand Held Produ
DisclaimerHand Held Products, Inc. d/b/a HHP (“HHP”) reserves the right to make changes in specifications and other information contained in this docu
1 - 4 IMAGETEAM™ 2020/5620 System ManualBattery Recommendations• Batteries are shipped approximately 30% to 60% charged and should be fully charged fo
IMAGETEAM™ 2020/5620 System Manual 1 - 5Base Charge ModeIn order for the battery to be charged, there must be enough voltage for the circuitry to work
1 - 6 IMAGETEAM™ 2020/5620 System ManualLinking Scanner to BaseWhen newly shipped or defaulted to factory settings, the base and scanner are not linke
IMAGETEAM™ 2020/5620 System Manual 1 - 7Locked Link ModeIf you link a scanner to a base using the Locked Link Mode, this blocks other scanners from be
1 - 8 IMAGETEAM™ 2020/5620 System ManualOut-of-Range AlarmDurationIf your scanner is out range of the base, an alarm sounds from both your base and sc
IMAGETEAM™ 2020/5620 System Manual 1 - 9Data Accumulation ModeScan the bar codes below to turn data accumulation (batch) mode on and off. If data acc
1 - 10 IMAGETEAM™ 2020/5620 System ManualThe tables below list the indication and cause of the LED illumination and beeps for the IT2020.Note: Chargin
IMAGETEAM™ 2020/5620 System Manual 1 - 11a radio signal with randomly changing frequencies, makes the cordless system highly responsive to a wide vari
1 - 12 IMAGETEAM™ 2020/5620 System ManualOut of Range and Back into Range with Data Accumulation Mode OnThe scanner may store a number of symbols (app
IMAGETEAM™ 2020/5620 System Manual 1 - 132. Disconnect the keyboard cable from the back of the terminal/computer.3. Connect the appropriate interface
Statement of Agency ComplianceThe IT2020/IT5620 system meets or exceeds the requirements of all applicable standards organizations for safe operation
1 - 14 IMAGETEAM™ 2020/5620 System ManualReading TechniquesThe scanner has a view finder that projects a bright red aiming beam that corresponds to it
IMAGETEAM™ 2020/5620 System Manual 1 - 15Note: After you scan one of the codes, power cycle the host terminal to have the interface in effect.Keyboard
1 - 16 IMAGETEAM™ 2020/5620 System ManualWand Emulation Plug & PlayIn Wand Emulation mode, the imager decodes the bar code then sends data in the
IMAGETEAM™ 2020/5620 System Manual 1 - 17IBM 4683 Ports 5B, 9B, and 17 InterfaceScan one of the following “Plug and Play” codes to program the IT5620
1 - 18 IMAGETEAM™ 2020/5620 System ManualConnecting the Base with USBA base can be connected to the USB port of a computer. 1. Connect the appropriat
IMAGETEAM™ 2020/5620 System Manual 1 - 19IBM SurePosScan one of the following “Plug and Play” codes to program the IT5620 for IBM SurePos (USB Hand He
1 - 20 IMAGETEAM™ 2020/5620 System ManualUSB HIDScan the following code to program the IT5620 for USB HID bar code scanners. Scanning this code chang
IMAGETEAM™ 2020/5620 System Manual 1 - 21Connecting the Base with Serial WedgeThe IT2020 uses TTL signal levels to wedge into an RS-232 serial network
1 - 22 IMAGETEAM™ 2020/5620 System ManualTo set up the serial wedge terminal ID, use the serial terminal ID 050 and follow the instructions on page 2-
IMAGETEAM™ 2020/5620 System Manual 2 - 12Terminal InterfacesTerminal IDIf your interface is not a standard PC AT, refer to "Supported Terminals&
If necessary, the user should consult the dealer or an experienced radio/television technician for additional suggestions. The user may find the fol
2 - 2 IMAGETEAM™ 2020/5620 System ManualSupported Terminals Terminal Model(s) Terminal IDDEC VT510, 520, 525 (PC style)005DEC VT510, 520, 525 (DEC sty
IMAGETEAM™ 2020/5620 System Manual 2 - 3* Default for IT2020-5.**It is best to use the Plug and Play bar codes, beginning on page 1-14 to program thes
2 - 4 IMAGETEAM™ 2020/5620 System ManualKeyboard CountryScan the appropriate country code below to program the keyboard for your country. As a general
IMAGETEAM™ 2020/5620 System Manual 2 - 5Please refer to Hand Held Products’ website (www.handheld.com) for complete keyboard country support informati
2 - 6 IMAGETEAM™ 2020/5620 System ManualEmulate External Keyboard should be scanned if you do not have an external keyboard (IBM AT or equivalent).Not
IMAGETEAM™ 2020/5620 System Manual 2 - 7Automatic Direct Connect Mode:This selection can be used if you have an IBM AT style terminal and the system i
2 - 8 IMAGETEAM™ 2020/5620 System ManualAll communication parameters between the scanner and terminal must match for correct data transfer through the
IMAGETEAM™ 2020/5620 System Manual 2 - 9RS-232 Word Length: Data Bits, Stop Bits, and ParityData Bits sets the word length at 7 or 8 bits of data per
2 - 10 IMAGETEAM™ 2020/5620 System ManualRS-232 HandshakingRS-232 Handshaking allows control of data transmission from the Imager using software comma
IMAGETEAM™ 2020/5620 System Manual 2 - 11The commands to which the scanner responds are listed on page 2-12. The <ESC> is a 1B in hex. A typic
Hand Held Products shall not be liable for use of our product with equipment (i.e., power supplies, personal computers, etc.) that is not CE marked a
2 - 12 IMAGETEAM™ 2020/5620 System ManualIT2020-5 Host Escape CommandsCommand Action<ESC> a Indicate as if successful menu change made<ESC>
IMAGETEAM™ 2020/5620 System Manual 2 - 13Wand EmulationWand Emulation ConnectionThe Wand Emulation Connection bar codes should be used if you want to
2 - 14 IMAGETEAM™ 2020/5620 System ManualWand Emulation Transmission RateThe transmission rate is limited by the terminal’s ability to receive data wi
IMAGETEAM™ 2020/5620 System Manual 2 - 15Wand Emulation IdleThe idle describes the state of the scanner when no data is being transmitted. When in Wa
2 - 16 IMAGETEAM™ 2020/5620 System ManualWand Emulation Overall ChecksumWhen this option is turned on, a computed check character is added at the end
IMAGETEAM™ 2020/5620 System Manual 3 - 13OutputScanner FunctionsGood Read IndicatorsBeeper – Good ReadThe beeper may be programmed On or Off in respo
3 - 2 IMAGETEAM™ 2020/5620 System ManualBeeper Pitch – Good ReadThe beeper pitch codes modify the pitch (frequency) of the beep the scanner emits on a
IMAGETEAM™ 2020/5620 System Manual 3 - 3Number of Beeps – Good ReadThe number of beeps of a good read can be programmed from 1 - 9. The same number o
3 - 4 IMAGETEAM™ 2020/5620 System ManualScanner Trigger ModesManual/Serial Trigger, Low PowerYou can activate the scanner either by pressing the trigg
IMAGETEAM™ 2020/5620 System Manual 3 - 5If there are no trigger pulls during the “scanner power time-out timer” interval, the scanner goes in power do
UL and cUL StatementUL listed UL1950 and CSA 22.2 No.950. cUL listed UL1950 and CSA 22.2 No 950.TÜV StatementTÜV or GS marked to EN60950 and EN60825
3 - 6 IMAGETEAM™ 2020/5620 System ManualReread DelayThis sets the time period before the scanner can read the same bar code a second time. Setting a
IMAGETEAM™ 2020/5620 System Manual 3 - 7Centering WindowUse the centering feature to narrow the scanner’s field of view so the scanner reads only the
3 - 8 IMAGETEAM™ 2020/5620 System ManualExample: If you have two bar codes next to one another and the centering window is set to 40% left edge and 60
IMAGETEAM™ 2020/5620 System Manual 3 - 93. LengthSpecify what length (up to 9999 characters) of data output will be acceptable for this symbology. Sc
3 - 10 IMAGETEAM™ 2020/5620 System ManualWhen the output sequence is Off, the bar code data is output to the host as the scanner decodes it. Note: Th
IMAGETEAM™ 2020/5620 System Manual 3 - 1162 code identifier for Code 399999 code length that must match for Code 39, 9999 = all lengths41 start charac
3 - 12 IMAGETEAM™ 2020/5620 System ManualMultiple SymbolsWhen this programming selection is turned On, it allows you to read multiple symbols with a s
IMAGETEAM™ 2020/5620 System Manual 4 - 14Data EditingPrefix/Suffix OverviewWhen a bar code is scanned, additional information is sent to the host com
4 - 2 IMAGETEAM™ 2020/5620 System ManualTo Add a Prefix or Suffix:Step 1. Scan the Add Prefix or Add Suffix symbol (page 4-3).Step 2. Determine the 2
IMAGETEAM™ 2020/5620 System Manual 4 - 3To Clear One or All Prefixes or Suffixes:You can clear a single prefix or suffix, or clear all prefixes/suffix
Required Safety LabelsIT5620
4 - 4 IMAGETEAM™ 2020/5620 System ManualSuffix SelectionsFunction Code TransmitWhen this selection is enabled and function codes are contained within
IMAGETEAM™ 2020/5620 System Manual 4 - 5Intercharacter DelayAn intercharacter delay of up to 495 milliseconds may be placed between the transmission o
4 - 6 IMAGETEAM™ 2020/5620 System ManualInterfunction DelayAn interfunction delay of up to 495 milliseconds may be placed between the transmission of
IMAGETEAM™ 2020/5620 System Manual 5 - 15Data FormattingData Format Editor IntroductionYou may use the Data Format Editor to change the scanner’s out
5 - 2 IMAGETEAM™ 2020/5620 System ManualNote: The wildcard for all terminal types is 099.Step 4. Code I.D.In the Appendix A, find the symbology to wh
IMAGETEAM™ 2020/5620 System Manual 5 - 3hex values for ASCII codes, see ASCII Conversion Chart (Code Page 1252) on page A-2.)F4 Send “xx” character “n
5 - 4 IMAGETEAM™ 2020/5620 System ManualE4 Replaces up to 15 characters in the data string with user specified charac-ters. Replacement continues unt
IMAGETEAM™ 2020/5620 System Manual 5 - 5Data FormatterWhen Data Formatter is turned off, the bar code data is output to the host as read (including pr
5 - 6 IMAGETEAM™ 2020/5620 System Manual
IMAGETEAM™ 2020/5620 System Manual 6 - 16SymbologiesIntroductionThis programming section contains the following menu selections. Refer to Chapter 10
''FCC ID: HD5MX2702BCanada IC1693BMX2702BHand Held Products, Inc.Skaneateles Falls, NY 13153www.hhp.com"Made in China"E153740US
6 - 2 IMAGETEAM™ 2020/5620 System ManualMessage LengthYou are able to set the valid reading length of some of the bar code symbologies. If the data
IMAGETEAM™ 2020/5620 System Manual 6 - 3Codabar<Default All Codabar Settings>CodabarCodabar Start/Stop CharactersStart/Stop characters identify
6 - 4 IMAGETEAM™ 2020/5620 System ManualWhen Check Character is set to Validate, but Don’t Transmit, the unit will only read Codabar bar codes printed
IMAGETEAM™ 2020/5620 System Manual 6 - 5Codabar Message LengthScan the bar codes below to change the message length. Refer to Message Length on page
6 - 6 IMAGETEAM™ 2020/5620 System ManualCode 39, continuedCode 39 Check CharacterNo Check Character indicates that the scanner reads and transmits bar
IMAGETEAM™ 2020/5620 System Manual 6 - 7Code 39, continuedCode 39 AppendThis function allows the scanner to append the data from several Code 39 bar c
6 - 8 IMAGETEAM™ 2020/5620 System ManualFull ASCIIIf Full ASCII Code 39 decoding is enabled, certain character pairs within the bar code symbol will b
IMAGETEAM™ 2020/5620 System Manual 6 - 9Code 39 Code PageCode pages define the mapping of character codes to characters. If the data received does no
6 - 10 IMAGETEAM™ 2020/5620 System ManualWhen Check Digit is set to Validate, but Don’t Transmit, the unit only reads Interleaved 2 of 5 bar codes pri
IMAGETEAM™ 2020/5620 System Manual 6 - 11Code 93< Default All Code 93 Settings >Code 93Code 93 Message LengthScan the bar codes below to change
iChapter 1 - Getting StartedAbout This Manual ... 1-1Unpacking the System ...
6 - 12 IMAGETEAM™ 2020/5620 System ManualCode 2 of 5<Default All Code 2 of 5 Settings>Code 2 of 5Code 2 of 5 Message LengthScan the bar codes be
IMAGETEAM™ 2020/5620 System Manual 6 - 13IATA Code 2 of 5, continuedIATA Code 2 of 5 Message LengthScan the bar codes below to change the message leng
6 - 14 IMAGETEAM™ 2020/5620 System ManualMatrix 2 of 5 Message LengthScan the bar codes below to change the message length. Refer to Message Length o
IMAGETEAM™ 2020/5620 System Manual 6 - 15Code 11, continuedCode 11 Message LengthScan the bar codes below to change the message length. Refer to Mess
6 - 16 IMAGETEAM™ 2020/5620 System ManualCode 128, continuedISBT 128 ConcatenationIn 1994 the International Society of Blood Transfusion (ISBT) ratifi
IMAGETEAM™ 2020/5620 System Manual 6 - 17Code 128 Function Code TransmitBy default, Code 128 function codes are not transmitted with Code 128 bar code
6 - 18 IMAGETEAM™ 2020/5620 System ManualTelepen Message LengthScan the bar codes below to change the message length. Refer to Message Length on page
IMAGETEAM™ 2020/5620 System Manual 6 - 19UPC A Number SystemThe numeric system digit of a U.P.C. symbol is normally transmitted at the beginning of th
6 - 20 IMAGETEAM™ 2020/5620 System ManualUPC A Addenda SeparatorWhen this feature is on, there is a space between the data from the bar code and the d
IMAGETEAM™ 2020/5620 System Manual 6 - 21UPC E0 and UPC E1Most U.P.C. bar codes lead with the 0 number system. For these codes, use the UPC E0 select
Commenti su questo manuale